PRICES ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE | SHIPPING NOT INCLUDED
Please note that selected items may not be in stock but you are welcome to still place an order. BHG Power will confirm lead time upon receipt of your order.

[qcf]
This unit including the battery box and 2 x 105 amp hour Royal 1150K Batteries

The PG series converts DC power into AC power. With a continuous output and compact design, the unit is deal for running TVs, Stereos, Laptop and computers and other home appliances.
The inverter will automatically transfer to inverter and provide power when AC supply is interrupted unexpectedly.

* Automatic line-to-battery switchover
* Charge current 10Amp/20amp adjustable
* Provides overload protection
* Auto restart while AC recovery
* Multi-function LED/LCD indications and buzzer alarms
* High efficient DC-to AC conversion, minimizing energy loss
* Intelligent 2 – stage charger control for efficient charging and preventing overcharge
* Super efficient, DC to AC conversion, minimizing charging losses
* Input voltage range selection option
* Fully automatic start operation
* High frequency technology
* Compact size and light weight
* Provides critical overload protection
* Eco-friendly & non-polluting (green device)
* Advanced technology optimizes battery life

Capacity VA/W 2400VA/1440W
Input Nominal voltage 230 VAC
Voltage range

170-280 VAC (Narrow Mode)

90 -280 VAC (Wide Mode)

Output Voltage 230 VAC
(Batt Mode) Voltage Regulation 10% / – 18%
Frequency 50 Hz or 60 Hz
(Batt Mode) Frequency Regulation +/- 0.1 Hz 24VOLT System
Output Waveform Modified Sinewave
Charger Charger Current 10 Amp +/- 1 Amp
DC Voltage 24V +/- 0.4V
Overcharge Protection 29V +/- 0.6V Fault
Transfer Time Typical 30 ms typical
Efficiency AC to DC >95%
DC to AC >80%
Indicator AC Mode Green LED
Battery Mode Yellow LED
Battery Charging Mode Green LED Flashing
every 2 seconds
Overload Red LED Flashing
every 0,5 seconds
Fault Red LED
Alarm Warning Low Battery! Alarm Sounds
Over 80% DOD every 2 seconds
Overload Alarm sounds
every 0,5 seconds
Fault Alarm Continuous
Protection Partial Protection Discharge, Overcharge
and Overload
Min/No Protection Surges, Spikes, Lightening
Physical Dimension (DxWxH) mm 395 x 405 x 425
Net Weight Kgs 67 Kgs
Environment Operating Environment 0-25°C Recom. 25°-40°C Max.
0-90% Relative Humidity
Non Condensing
Noise Level <55 dB when charging